Stadtwerke Neumünster
CyberattackAccording to media reports, all systems were shut down after a cyberattack.
Energy utilities & municipal providers · EnWG § 5c · KRITIS · NIS2
Administrative IT and grid operations sit side by side. We test both sides and the crossing in between.
Electricity and gas networks have to be certified against the IT-Sicherheitskatalog.
The catalogue requires recertification. A pentest beforehand finds the gaps first.
KRITIS installations (power plants from 104 MW): duties via the IT-Sicherheitskatalog.
Amber marks the places where IT and OT sit against each other. That is where testing happens least often.
Contract data and meter readings, publicly reachable.
Office network, email, billing. An attack spreads from here.
VPN and vendor access points are the bridge from IT into OT.
Control and data storage, barely staffed at night.
Legacy protocols without segmentation from IT.
No staff on site: fence, gate and access control decide.
The two worlds follow different priorities. An assessment that only applies IT concepts to OT misses the real risks.
| Conventional IT | OT, SCADA & remote control systems | |
|---|---|---|
| Priority | Confidentiality of data | Availability of supply |
| Patches | Can usually be rolled out promptly | Often impossible to apply for years (certification, vendor support) |
| Protocols | Standard protocols (TCP/IP, HTTPS) | Proprietary and legacy protocols with no built-in security |
| Maintenance windows | Short maintenance windows are feasible | Only in tightly planned windows, downtime is not an option |
According to media reports, all systems were shut down after a cyberattack.
The internal network and customer portal went offline; according to reports, the data later surfaced on the dark web.
According to reports, an arson attack on power cables affected around 45,000 households.
Based on public reporting. Access Granted was not involved in these incidents.
Supply reliability always comes first. That is why we test OT and remote control components noticeably more carefully than plain IT.
Customer portals, administrative IT and remote maintenance.
Manual: authentication, access rights, segmentation, hardening.
Every finding by severity and impact on supply.
Defined together: what gets actively tested.
We read protocols passively. Active tests only in agreed windows.
A fixed contact accompanies every test and can stop it immediately.
Recommendations, a management summary and every finding mapped to the catalogue.
Final report listing all findings, each rated by severity, exploitability and its impact on the reliability of supply
Every finding mapped to the IT-Sicherheitskatalog, supplemented by KRITIS and NIS2 as far as they are relevant to you
Management summary for leadership, IT management and grid operations
Certificate naming the client, test period, scope and a reference code, verifiable at access-granted.de/verify
Access to substations, control rooms and data centres.
SCADA, remote control technology and control systems, availability first.
Segmentation of IT/OT/administration, access rights, hardening.
The IT-Sicherheitskatalog does not name any particular test method explicitly, but it does require a certified information security management system and regular proof of adequate protective measures. In practice, a penetration test is the standard instrument for backing up this proof on the technical side.
OT systems prioritise availability over confidentiality, often run on legacy protocols without any security mechanisms and do not tolerate aggressive scans. That is why we test far more carefully: mostly passively, actively only in tightly agreed windows outside critical operating hours, and always with a defined emergency contact.
Yes, as part of the Physical Pentest module. We check access control, the security of fences and gates, and whether someone could convincingly pass themselves off as a maintenance technician and get in without being noticed. Who on your side is in the know, and who calls the test off if in doubt, we agree together beforehand.
No. The IT-Sicherheitskatalog requires recurring recertification on a three-year cycle. We recommend building the pentest firmly into your certification rhythm instead of only kicking it off shortly before the next audit.
In 30 minutes we clarify your scope and what counts for the IT-Sicherheitskatalog. Free of charge.
Read more online: access-granted.de/en/branchen/energy